Light-scanning photoacoustic densitometer applied to protein determination.
نویسندگان
چکیده
منابع مشابه
Coregistered photoacoustic-ultrasound imaging applied to brachytherapy.
Brachytherapy is a form of radiation therapy commonly used in the treatment of prostate cancer wherein sustained radiation doses can be precisely targeted to the tumor area by the implantation of small radioactive seeds around the treatment area. Ultrasound is a popular imaging mode for seed implantation, but the seeds are difficult to distinguish from the tissue structure. In this work, we dem...
متن کاملScanning acoustic-photoacoustic microscopy using axicon transducers
A dual mode scanning acoustic microscope is investigated, yielding simultaneously images with optical and acoustical contrast. Short laser pulses are used to excite acoustic waves in a sample for the photoacoustic imaging mode. At the same time the pulses irradiate a conical target generating limited diffraction acoustic waves (X-waves) for large depth of field ultrasound imaging. For photoacou...
متن کاملPhotoacoustic imaging based on MEMS mirror scanning
A microelectromechanical systems (MEMS)-based photoacoustic imaging system is reported for the first time. In this system, the MEMS-based light scanning subsystem and a ring-shaped polyvinylidene fluoride (PVDF) transducer are integrated into a miniaturized probe that is capable of three-dimensional (3D) photoacoustic imaging. It is demonstrated that the imaging system is able to image small ob...
متن کاملScanning tunneling microscopy applied to optical surfaces.
The technique of scanning tunneling microscopy has been applied to topographic mapping of two optical surfaces: a ruled grating replica and a diamond-turned gold mirror. We have demonstrated the ability of the scanning tunneling microscope to measure surface topography of a ruled-grating replica over an area of 2 microm x 2 microm. Furthermore, surface structure on a diamond-turned gold mirror ...
متن کاملThree-dimensional arbitrary trajectory scanning photoacoustic microscopy.
We have enhanced photoacoustic microscopy with three-dimensional arbitrary trajectory (3-DAT) scanning, which can rapidly image selected vessels over a large field of view (FOV) and maintain a high signal-to-noise ratio (SNR) despite the depth variation of the vessels. We showed that hemoglobin oxygen saturation (sO2 ) and blood flow can be measured simultaneously in a mouse ear in vivo at a fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1986
ISSN: 0910-6340,1348-2246