Lifetime measurement of the41+state ofNi58with the recoil distance method

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sub-Nanosecond Lifetime Measurement Using the Recoil-Distance Method

The electromagnetic properties of low-lying nuclear states are a sensitive probe of both collective and single-particle degrees of freedom in nuclear structure. The recoil-distance technique provides a very reliable, direct and precise method for measuring lifetimes of nuclear states with lifetimes ranging from less than one to several hundred picoseconds. This method complements the powerful, ...

متن کامل

Recoil-distance lifetime measurement in 37Cl

2014 Using the recoil-distance technique in the 27Al(12C, 2p)37Cl reaction, mean lives of (19.6 ± 3.0) ps for the 7/2-, 3 103-keV state and (32.8 ± 2.0) ps for the 9/2-, 4 011-keV state in 37Cl have been measured. The strength of the M2 decay from the 3 103 keV level appears to be the strongest among known M2 transitions in 2s-ld nuclei. An upper limit of 0.8 ps for the feeding time in the fusi...

متن کامل

Precision Lifetime Measurements Using the Recoil Distance Method

The recoil distance method (RDM) for the measurements of lifetimes of excited nuclear levels in the range from about 1 ps to 1000 ps is reviewed. The New Yale Plunger Device for RDM experiments is introduced and the Differential Decay Curve Method for their analysis is reviewed. Results from recent RDM experiments on SD bands in the mass-190 region, shears bands in the neutron deficient lead is...

متن کامل

Recoil - distance lifetime measurements of V levels

Lifetimes for a number of level. s in 4 V have been measured using the recoil-distance technique. The experimental results for the mean lifetimes are 8.8+1.4 psec for the 428keV 5+ level, 21.6+1.1 psec for the 613-keV 4+ level, 111+9 psec for the 627-keV 6+ level, 6.7+ 1.8 psec for the 1056-keV 3 level, and 6, 5+ 0.5 psec for the 1099-keV 4~ ~ level. Lifetime l.imits were measured for other lev...

متن کامل

buckling of viscoelastic composite plates using the finite strip method

در سال های اخیر، تقاضای استفاده از تئوری خطی ویسکوالاستیسیته بیشتر شده است. با افزایش استفاده از کامپوزیت های پیشرفته در صنایع هوایی و همچنین استفاده روزافزون از مواد پلیمری، اهمیت روش های دقیق طراحی و تحلیل چنین ساختارهایی بیشتر شده است. این مواد جدید از خودشان رفتارهای مکانیکی ارائه می دهند که با تئوری های الاستیسیته و ویسکوزیته، نمی توان آن ها را توصیف کرد. این مواد، خواص ویسکوالاستیک دارند....

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review C

سال: 2016

ISSN: 2469-9985,2469-9993

DOI: 10.1103/physrevc.94.024340