Lidar arc scan uncertainty reduction through scanning geometry optimization
نویسندگان
چکیده
منابع مشابه
Lidar arc scan uncertainty reduction through scanning geometry optimization
Doppler lidars are frequently operated in a mode referred to as arc scans, wherein the lidar beam scans across a sector with a fixed elevation angle and the resulting measurements are used to derive an estimate of the nminute horizontal mean wind velocity (speed and direction). Previous studies have shown that the uncertainty in the measured wind speed originates from turbulent wind fluctuation...
متن کاملInteractive comment on “Lidar arc scan uncertainty reduction through scanning geometry optimization” by H. Wang et al
This paper concerns estimation of the uncertainty of the mean wind speed when estimated from a Doppler lidar arc scan, i.e. a certain fraction of a normal conical scan. The subject is timely, as more and more scanning Doppler lidars are used, especially in the wind energy industry. The authors has got accepted a similar paper in Journal of Oceanic and Atmospheric Technology (Wind Measurements f...
متن کاملScan Test Cost and Power Reduction Through Systematic Scan Reconfiguration
This paper presents segmented addressable scan (SAS), a test architecture that addresses test data volume, test application time, test power consumption, and tester channel requirements using a hardware overhead of a few gates per scan chain. Using SAS, this paper also presents systematic scan reconfiguration, a test data compression algorithm that is applied to achieve 10× to 40× compression r...
متن کاملScanning Moving objecTS USing LiDaR
LiDAR becoming one of the most commonly mentioned technologies within the geospatial community and many others, while being used in a wide variety of applications—some of which were not even thought of 10 years ago. This is part of a transition from 2D representation of our surroundings to 3D with LiDAR technologies playing a key role. With the advancements in instrumentation and technology, be...
متن کاملOptimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atmospheric Measurement Techniques
سال: 2016
ISSN: 1867-8548
DOI: 10.5194/amt-9-1653-2016