Microbial contamination of surgical instruments used for laparotomy.
BACKGROUND The aim of this study was to determine the risk of contamination of surgical instruments according to the type of instrument and the surgical procedure. METHODS Microbiologic examination was conducted on 140 pairs of forceps used in 24 elective laparotomies. These included 60 pairs of tissue forceps and 80 pairs of DeBakey forceps. Microbes on their surface were recovered using a m...
متن کاملMicrobial contamination of musical wind instruments.
Retrospective and prospective studies were used to assess the numbers, types and persistence of microbes that contaminate wind instruments. All previously played instruments (n = 20) harbored viable bacteria as well as mold and/or yeast. Reedinstruments consistently carried higher microbial loads than did flutes or trumpets. Instruments played within the previous three days bore typical mouth f...
متن کاملOn Indian Surgical Instruments; Illustrated
ON INDIAN SURGICAL INSTRUMENTS; ILLUSTRATED. By E. Temple Weight, M.D., F.R.C.S. (Exam.) Bengal Medical Service. The illustration represents fourteen instruments used by native medical practitioners as follows: No. 1. Lithotomy knife, inches long. 2. Do. do. 9 ,, 3. Do. forceps, 8f ,, 4. Do. scoop. 9 5. Goat's horn, used instead of No. 4, 6j inches long. 6. Blacksmith's tooth forceps, 10 inches...
متن کامل: the effect of sericin levels (silk glue protein) on rate of in vitro maturation, fertilization and culture of sheep oocytes
هدف از آزمایش اول بررسی اثر سطوح مختلف سریسین [0 (control), 0.1, 0.5, 1.0, 2.5 %] افزوده شده به محیط , ivm بر cumulus cell expansion، بلوغ هسته و توسعه متوالی جنین، در گوسفندان نژاد سنجابی در فصل تولید مثلی می باشد. از سرگیری میوز به وسیله خارج شدن اولین پولار بادی اندازه گیری و هم چنین درصد رسیدن جنین های دو سلولی به مرحله کلیواژ و بلاستوسیت نیز به عنوان نشانه ای از میزان شایستگی توسعه اولیه ج...
Microbial contamination of suction tubes attached to suction instruments and preventive methods.
We investigated the microbial contamination of suction tubes attached to wall-type suction instruments. Microbial contamination of suction tubes used for endoscopy or sputum suction in hospital wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (n=33) before disinfection were contaminated with 10(...