Legionella in industrial cooling towers: monitoring and control strategies
نویسندگان
چکیده
منابع مشابه
Legionella spp. in Puerto Rico cooling towers.
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable o...
متن کاملLegionella species isolated from cooling towers in Kuala Lumpur.
Three building complexes in Kuala Lumpur were surveyed for the presence of legionellae in cooling towers. The organisms were grown from 12 out of 46 samples of water collected from 30 towers. L. pneumophila serogroups 1 and 7 were the commonest serogroups isolated. None belonged to the Pontiac subgroup of L. pneumophila serogroup 1.
متن کاملAn alkaline approach to treating cooling towers for control of Legionella pneumophila.
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances...
متن کاملIndustrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.
The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC) at 36 °C was performed from June to Octob...
متن کاملIsolation of Legionella pneumophila from hospital cooling towers in Johor, Malaysia.
Water-based cooling towers and their water supply at two hospitals in Johor were surveyed for the presence Legionella pneumophila. L. pneumophila were grown from 19 (76%) out of 25 collected water samples. One hospital cooling tower was contaminated with L. pneumophila serogroup 1.