Left breast irradiation with tangential intensity modulated radiotherapy (t-IMRT) versus tangential volumetric modulated arc therapy (t-VMAT): trade-offs between secondary cancer induction risk and optimal target coverage
نویسندگان
چکیده
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملTangential volumetric modulated arc therapy technique for left-sided breast cancer radiotherapy
BACKGROUND The aim of the present study was to introduce a new restricted tangential volumetric modulated arc therapy (tVMAT) technique for whole breast irradiation and compare its dosimetric properties to other currently used breast cancer radiotherapy techniques. METHOD Ten consecutive women with left-sided breast cancer were enrolled in this retrospective study. Four treatment plans were g...
متن کاملComparative analysis of SmartArc‐based dual arc volumetric‐modulated arc radiotherapy (VMAT) versus intensity‐modulated radiotherapy (IMRT) for nasopharyngeal carcinoma
The purpose of this study was to evaluate and quantify the planning performance of SmartArc-based volumetric-modulated arc radiotherapy (VMAT) versus fixed-beam intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) using a sequential mode treatment plan. The plan quality and performance of dual arc-VMAT (DA-VMAT) using the Pinnacle3 Smart-Arc system (clinical version 9.0; P...
متن کاملTangential intensity modulated radiation therapy (IMRT) to the intact breast
INTRODUCTION Inverse-planned intensity modulated radiation therapy (IP-IMRT) has potential benefits over other techniques for tangential intact breast radiotherapy. Possible benefits include increased homogeneity, faster planning time, less inter-planner variability and lower doses to organs at risk (OAR). We therefore conducted a pilot study of previously treated intact breast patients to comp...
متن کاملIntensity modulated radiation therapy versus volumetric intensity modulated arc therapy
The advanced developments in external beam radiation therapy (EBRT) over the past few decades have improved dose conformity to the target while minimizing dose to the surrounding organs at risk (OAR). Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are two commonly used EBRT techniques to treat cancer. In sliding window (SW) or dynamic IMRT, each radiati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Oncology
سال: 2019
ISSN: 1748-717X
DOI: 10.1186/s13014-019-1363-4