Lead(II)-Selective Coated Graphite Electrode Based on Benzo-18-crown-6
نویسندگان
چکیده
منابع مشابه
Sn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6
We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...
متن کاملsn (ii) ion- selective membrane electrode based on dibenzo-18-crown-6
we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...
متن کاملHydration to benzo-15-crown-5, benzo-18-crown-6 and the benzo-18-crown-6-potassium ion complex in the low-polar organic solvents.
The coextraction of water with benzo-15-crown-5 (B1SC5), benzo-18-crown-6 (B18C6) and the B18C6-K+ complex into seven low-polar solvents, i.e., carbon tetrachloride (CTC), chloroform (CF), dichloromethane (DCM), 1,2-dichloroethane (1,2-DCE), benzene (BZ), chlorobenzene (CB) and o-dichlorobenzene (o-DCB), has been investigated. The mean hydration number, nH2O, of these solutes in the water-satur...
متن کاملA new lead(II)-selective PVC-coated graphite rod electrode based on a Schiff base complex.
A new lead(II)-selective electrode has been developed based on bis(acetylacetone)-p-phenylenediamine-lead(II) [LPb(NO3)2]H2O complex ionophore as a sensing material, dioctylphthalate (DOP) as a solvent mediator and PVC as a matrix. This electrode exhibits a linear Nernstian response over the concentration range of 1 x 10(-5)-1 x 10(-1) mol l(-1) of Pb(II) cation, with a cationic calibration slo...
متن کاملDetermination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore
In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Asian Journal of Chemistry
سال: 2013
ISSN: 0970-7077,0975-427X
DOI: 10.14233/ajchem.2013.13109