LCLR FILTER DESIGN AND MODELLING FOR HARMONIC MITIGATION IN INTERCONNECTED MICRO GRID SYSTEM
نویسندگان
چکیده
منابع مشابه
LCL Filter Design and Performance Analysis for Grid Interconnected Systems
-The use of power converters is very important in maximizing the power transfer from renewable energy sources such as wind, solar, or even a hydrogen-based fuel cell to the utility grid. A LCL filter is often used to interconnect an inverter to the utility grid in order to filter the harmonics produced by the inverter. Even though there is an extensive amount of literature available describing ...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولReactive Power Sharing and Harmonic Voltage Modification in Single Phase Island Micro-Grid with Drop Control
Abstract: When several parallel inverters are in islands operating mode, the droop control scheme is usually used to control the inverters. The droop control method enables the inverters of a Micro-Grid to control the voltage and frequency of the network in a decentralized regulation behavior. The drop control method also enables the inverters to share the required active and reactive powers of...
متن کاملOff-grid Energy System Design for Residential Units
For decreasing the amount of air pollution and green gas emission and saving fossil fuels resource, one of the ways is extending renewable energy utilization. Hence, this yields to growth and development of Photovoltaic systems. Nowadays due to increasing electrical energy requirements and ability to privately providing required energy, the use of solar energy and its electrical power creativit...
متن کاملHigh Performance Seven Level Active Shunt Filter for Harmonic Mitigation
This paper deals with the simulation of a shunt active filter using seven level cascaded H-bridge multilevel inverter. The proposed active filter topology can also produce seven voltage levels, which significantly reduces the switching current ripple and the size of passive components. The seven level active shunt filter provides compensation of load power factor and current harmonics. For comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Engineering and Technology
سال: 2015
ISSN: 2321-7308,2319-1163
DOI: 10.15623/ijret.2015.0404122