LCL Interface Filter Design for Shunt Active Power Filters
نویسندگان
چکیده
منابع مشابه
A Novel Design and Optimization Method of an $LCL$ Filter for a Shunt Active Power Filter
This paper analyses the characteristics of LCL filter in active power filter (APF) and provides an accurate for mula to determine the resonant frequency of system. Based on a single-phase equivalent circuit model, a systematic approach to design APF with LCL filter is proposed. Total inductance is determined by the capability of APF. Moreover, damping ratio, resonant frequency and attenuation d...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملShunt Active Filter for Power Quality Improvement
This paper describes the development of a low cost shunt active power filter with digital control, which allows dynamic power factor correction and both harmonics and zero-sequence current compensation. The active filter controller is based on the instantaneous power theory (p-q theory) and was implemented using a standard 16 bits microcontroller. The p-q theory is introduced followed by the pr...
متن کاملShunt Active Power Filter Design using Genetic Algorithm Method
-This paper deals with the active power filter design controlled by using hysteresis technique. The genetic algorithm is used to design the controllers to minimize the %THD of the source current. The results are compared with that designed from Ingram and Round approach. The simulation results confirm that the genetic algorithm can provide the minimum %THD of the source current compared with th...
متن کاملDesign of a Four-Branch LCL-Type Grid-Connecting Interface for a Three-Phase, Four-Leg Active Power Filter
Compared with the three-phase, two-split-capacitor active power filter (3P2C-APF), the three-phase, four-leg active power filter (3P4L-APF) has been widely used in three-phase, four-wire grid utility for power quality control due to its numerous advantages, such as higher current output capability, particularly in phase N, lower current and easier voltage control on the DC-side. However, design...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Electrical and Computer Engineering
سال: 2010
ISSN: 1582-7445,1844-7600
DOI: 10.4316/aece.2010.03009