Lateral shear strength of rectangular RC columns subjected to combined P-V-M monotonic loading
نویسندگان
چکیده
منابع مشابه
Seismic Performance of Square RC Bridge Columns under Combined Loading including Torsion with Low Shear
During earthquake excitations, reinforced concrete bridge columns can be subjected to a combination of axial load, shear force, flexural moments, and torsional moments. The torsional moment can be much more significant in columns of bridges that are skewed, curved, have unequal spans, or unequal column heights. Combined loading including torsion can result in complex flexural and shear failure ...
متن کاملNumerical Simulation of FRP-Jacketed RC Columns Subjected to Cyclic Loading
This paper presents a study that forms part of an ongoing project on the seismic retrofit of reinforced concrete (RC) structures with fibre-reinforced polymer (FRP). In this study, a stress-strain model for FRP-confined concrete subjected to cyclic loading was implemented into OpenSees to support the performance-based design of FRP jackets for the seismic retrofit of RC columns/structures. Init...
متن کاملA unified approach for determining the ultimate strength of RC members subjected to combined axial force, bending, shear and torsion
This paper uses experimental investigation and theoretical derivation to study the unified failure mechanism and ultimate capacity model of reinforced concrete (RC) members under combined axial, bending, shear and torsion loading. Fifteen RC members are tested under different combinations of compressive axial force, bending, shear and torsion using experimental equipment designed by the authors...
متن کاملBehavior of High-Strength Concrete Rectangular Columns
This paper summarizes the test results of an extensive research program sponsored by the US Transportation Research Board of the National Research Council to examine the behavior of high-strength concrete rectangular columns subjected to concentric and eccentric loading conditions. The variables considered in this investigation were concrete strength ranging from 7.9 ksi (55 MPa) to 16.5 ksi (1...
متن کاملConfinement Characteristics of Rectangular FRP-Jacketed RC Columns
In this study, FRP jackets were investigated for their confinement effectiveness on rectangular RC columns. Thirteen reduced-scale short columns were tested to failure in axial compression. Variables investigated include: the type of fibers (AFRP, CFRP or GFRP), the thickness of the jacket, the aspect ratio of the rectangular cross section and the radii of the corners. For square columns, GFRP ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the New Zealand Society for Earthquake Engineering
سال: 2020
ISSN: 2324-1543,1174-9857
DOI: 10.5459/bnzsee.53.4.227-241