We report an extremely rare presentation of late-onset endophthalmitis in a young adult patient with an unexposed Ahmed tube implant. The implant was inserted 11 years prior to presentation. There was no history of trauma or any obvious exposure on clinical examination and the tube plate was filled with purulent material. After aqueous and vitreous tap, the patient underwent intracameral, intra...
متن کاملConcurrent endophthalmitis and orbital cellulitis in a child with congenital glaucoma and a glaucoma drainage device.
A 3-year-old monocular boy with a history of congenital glaucoma and aqueous shunt implantation presented with periorbital swelling, erythema, and purulent discharge in his seeing right eye. Examination revealed an extensive hypopyon. Computed tomography (CT) showed right-sided proptosis, and a displaced aqueous shunt device deep in the orbit. Significant purulent fluid was encountered when the...
متن کاملIntraocular and extraocular hemorrhage associated with ligature release of non-valved glaucoma drainage implant
Purpose To report a rare complication of non-valved glaucoma drainage device surgery. Observations An 85-year-old pseudophakic white male presented with painless vision loss and bloody tears. He was 5 weeks removed from uncomplicated non-valved glaucoma drainage device (Baerveldt 101-350, [AMO, Santa Clara, CA]). There was serosanguinous discharge without apparent source and a 25% layering hy...
متن کاملLate-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma
Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with p...
متن کاملLate-onset bleb-associated endophthalmitis and continuous positive airway pressure
Purpose To raise awareness of a possible association between continuous positive airway pressure (CPAP) devices and postoperative bleb-related infection. Observations A 57-year old patient on CPAP presented with unilateral bleb-associated endophthalmitis 32 months after routine ExPress Trabeculectomy with mitomycin C. The offending organism, Streptococcus mitis, is a nonmotile and generally n...