Late driveline left ventricular assist device infection treated with frozen-and-thawed allogeneic platelet gel.

In this case report, we report the application of frozen-and-thawed allogeneic platelet gel (PLT-gel) to treat a late driveline exit site infection in a 56-year old patient supported by a Heartware-HVAD left ventricular assist device. The treatment duration was 4 weeks and at the follow-up the skin around the exit site was free from further infection. PLT-gel can be used to treat local infectio...

متن کامل

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.

OBJECTIVES To determine if driveline infection is related to dressing change frequency in hospitalized adult patients with newly implanted left ventricular assist devices (LVAD). BACKGROUND Guidelines do not exist for the frequency of driveline exit-site dressing change in hospitalized patients resulting in wide variation in practice. METHODS A retrospective chart review was conducted on 68...

متن کامل

Platelet inhibition with ticagrelor for left ventricular assist device thrombosis.

A lthough considered standard therapy for Stage D heart failure since 2008, the continuous, axial flow HeartMate II (HMII) left ventricular assist device (LVAD) has recently been associated with unexpected rise in rates of pump thrombosis. 1 With an incidence of 0.01 to 0.11 events per patient-year, LVAD thrombosis responds to intensification of antithrombotic therapy with unfractionated hepari...

متن کامل

VeraFlo Negative Pressure Wound Therapy with Household Bleach for Refractory Driveline Infection in a Patient with Left Ventricular Assist Device

Driveline infections and sepsis are amongst the most common causes of morbidity and mortality in a patient with a left ventricular assist device. In this case, we present a patient with a multi drug resistant pseudomonas aeruginosa driveline exit site infection. Initially, it was treated with dual antibiotics, followed by surgical debridement utilizing Dakin’s solution irrigation and standard n...