Laser ion source for high brightness heavy ion beam
نویسندگان
چکیده
منابع مشابه
High-brightness Cs focused ion beam from a cold-atomic-beam ion source
We present measurements of focal spot size and brightness in a focused ion beam system utilizing a laser-cooled atomic beam source of Cs ions. Spot sizes as small as (2.1 ± 0.2) nm (one standard deviation) and reduced brightness values as high as (2.4 ± 0.1) × 107 A m-2 Sr-1 eV-1 are observed with a 10 keV beam. This measured brightness is over 24 times higher than the highest brightness observ...
متن کاملHigh brightness inductively coupled plasma source for high current focused ion beam applications
A high brightness plasma ion source has been developed to address focused ion beam !FIB" applications not satisfied by the liquid metal ion source !LMIS" based FIB. The plasma FIB described here is capable of satisfying applications requiring high mill rates !!100 "m3/s" with non-gallium ions and has demonstrated imaging capabilities with sub100-nm resolution. The virtual source size, angular i...
متن کاملECR Plasma Source for Heavy Ion Beam Charge Neutralization*
Philip C. Efthimion, Erik Gilson, Larry Grisham, Pavel Kolchin and Ronald C. Davidson Plasma Physics Laboratory Princeton University, Princeton, New Jersey, 08543, USA Simon Yu and B. Grant Logan Lawrence Berkeley National Laboratory University of California, Berkeley, California, 94720, USA Highly ionized plasmas are being considered as a medium for charge neutralizing heavy ion beams in order...
متن کاملMeasurement of Ion Beam from Laser Ion Source for Rhic Ebis
Laser ion source (LIS) is a candidate of the primary ion source for the RHIC EBIS. LIS will provide intense charge state 1+ ions to the EBIS for further ionization. We measured plasma properties of a variety of atomic species from C to Au using the second harmonics of Nd:YAG laser (532 nm wave length, up to 0.5 J / 6 ns). Since properties of laser produced plasma is different from different spe...
متن کاملExperiments on neutralized beam extraction from a laser ion source
Particle loss due to space charge effects is a severe problem in the low energy section of accelerators. The extraction system and beam transport sections are the most sensitive parts. Especially for the case of a laser-ion source (LIS) the extraction of ions from very dense plasma can lead to a high current density in the extraction gap. To make use of this high current density (i.e. to maximi...