Metallurgical consideration on the calibration curve for binary alloy samples in low-pressure argon laser-induced plasma spectrometry.
The composition dependence of the emission intensities was investigated in Cu-Ni as well as Ni-Zn binary alloy samples when a low-pressure argon laser-induced plasma was employed as the excitation source. The calibration curve in the Cu-Ni alloy system gave a linear relationship, implying that the selective evaporation of Cu or Ni atoms was caused less in those alloys having several chemical co...
متن کاملapplication and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولSecurity characterisation of a hardened AES cryptosystem using a laser
The AES is a standard encryption algorithm used in numerous cryptographic systems like smart cards, TPMs as well as in protocols like WPA2 or OpenSSL. Measuring the robustness of AES implementations against physical attacks is of utmost import-ance in order to guarantee the security of the system into which the AES is used. In this article, we describe how a hardware AES, embedding countermeasu...
متن کاملRobust Standard Errors in Small Samples: Some Practical Advice∗
In this paper we discuss the properties of confidence intervals for regression parameters based on robust standard errors. We discuss the motivation for a modification suggested by Bell and McCaffrey (2002) to improve the finite sample properties of the confidence intervals based on the conventional robust standard errors. We show that the Bell-McCaffrey modification is a natural extension of a...
متن کاملLaser Tracker Calibration Using Coordinate Measuring Machine
This paper presents the achievement of a China NSFC project. A technique to calibrate laser tracker using CMM has been developed. A laser tracker with working range of 35m can be calibrated accurately and quickly using a CMM with working range of 1m. Studies have shown that angular errors are the key contributor to measuring errors of laser tracker. A device to measure angular errors of laser t...