Large-Volume Sample Sweeping with a High Theoretical Plate Number Using a Coupled-Capillary in Capillary Electrophoresis
نویسندگان
چکیده
منابع مشابه
Large-volume sample sweeping with a high theoretical plate number using a coupled-capillary in capillary electrophoresis.
A large-volume sample injection (> 5 microL) with an extremely high theoretical plate number (N > 10(7)) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 microm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED ( approximately 2 mW) was used as the fluorescence excitation source. As a result, the theoretica...
متن کاملUnlimited-volume electrokinetic stacking injection in sweeping capillary electrophoresis using a cationic surfactant.
Sweeping is an effective and convenient way for online sample preconcentration in micellar electrokinetic chromatography. The usual procedure includes a hydrodynamic injection step carried out by applying pressure to the sample vial followed by the subsequent sweeping and separation processes. The injected sample volume is limited by the dimensions of the capillary because a part of the capilla...
متن کاملMicrobeam-coupled capillary electrophoresis.
Within the first few microseconds following a charged particle traversal of a cell, numerous oxygen and nitrogen radicals are formed along the track. Presented here is a method, using capillary electrophoresis, for simultaneous measurement, within an individual cell, of specific reactive oxygen species, such as the superoxide radical ([Formula: see text]) as well as the native and oxidised form...
متن کاملAnalysis of Three Compounds in Flos Farfarae by Capillary Electrophoresis with Large-Volume Sample Stacking
The aim of this study was to develop a method combining an online concentration and high-efficiency capillary electrophoresis separation to analyze and detect three compounds (rutin, hyperoside, and chlorogenic acid) in Flos Farfarae. In order to get good resolution and enrichment, several parameters such as the choice of running buffer, pH and concentration of the running buffer, organic modif...
متن کاملOn-line sample preconcentration by sweeping with dodecyltrimethylammonium bromide in capillary zone electrophoresis.
On-line sample preconcentration of oligonucleotides with a new sweeping carrier was developed by using dodecyltrimethylammonium bromide (DTAB) below the critical micelle concentration (CMC). The sweeping results with DTAB below and above the CMC were compared. The use of DTAB below the CMC benefits the preconcentration of the oligonucleotides, while the use of DTAB above the CMC is good for hyd...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2006
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.22.557