Large-area measurements of CIB power spectra with Planck HFI maps
نویسندگان
چکیده
منابع مشابه
Measuring CMB polarisation with the Planck HFI
The Planck High Frequency Instrument (HFI) is the most sensitive instrument currently being built for the measurement of Cosmic Microwave Background anisotropies. In addition to unprecendented sensitivity to CMB temperature fluctuations, the HFI has polarisation-sensitive detectors in 3 frequency channels (143, 217 and 353 GHz), which will constrain full-sky polarised emission of the CMB and fo...
متن کاملPlanck 2013 results. IX. HFI spectral response
The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (including the level of out-of-band signal rejection) of all HFI detectors to a known source of electromagne...
متن کاملPlanck pre-launch status: The optical architecture of the HFI
The Planck High Frequency Instrument, HFI, has been designed to allow a clear unobscured view of the CMB sky through an offaxis Gregorian telescope. The prime science target is to measure the polarized anisotropy of the CMB with a sensitivity of 1 part in 10 with a maximum spatial resolution of 5 arcmin (Cl ∼ 3000) in four spectral bands with two further high-frequency channels measuring total ...
متن کاملImplications of Planck and Map Measurements on Sparticle Spectra
Future sattelite (MAP and Planck), balloon and ground based experiments will determine the basic cosmological parameters within a few percent. We examine here the effect of this on constraining the SUSY parameter space for supergravity R-parity conserving models (with tan β ≤ 25) for the cases of νCDM and ΛCDM cosmological models. For the νCDM (ΛCDM) models, the gluino mass is restricted bymg̃ <...
متن کاملPlanck 2013 results. VII. HFI time response and beams
This paper characterizes the effective beams, the effective beam window functions and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is the angular response including the effect of the optics, detectors, data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain that is required to reco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Proceedings of the International Astronomical Union
سال: 2015
ISSN: 1743-9213,1743-9221
DOI: 10.1017/s1743921316004488