Laminar flow characterization using low-field magnetic resonance techniques

نویسندگان

چکیده

Laminar flow velocity profiles depend heavily on fluid rheology. Developing methods of laminar characterization, based low-field magnetic resonance (MR), contribute to the widespread industrial application MR technique in In this paper, we outline design a low-cost, palm-sized permanent magnet with 1H frequency 20.48 MHz measure flow. The consists two disk magnets, which were each tilted at an angle 1° from edge separation 1.4 cm generate constant gradient, 65 G/cm, direction Subsequently, series process methods, for measurements, proposed characterize Newtonian and non-Newtonian flows pipe, including phase-based method, magnitude-based spectrum method. accuracy was validated by simulations, experiments Poiseuille shear-thinning designed magnet. new profile are advantageous because hardware measurement simple will result portable instrument. Although governing equations complicated, data analysis is straightforward.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring cerebral blood flow using magnetic resonance imaging techniques.

Magnetic resonance imaging techniques measuring CBF have developed rapidly in the last decade, resulting in a wide range of available methods. The most successful approaches are based either on dynamic tracking of a bolus of a paramagnetic contrast agent (dynamic susceptibility contrast) or on arterial spin labeling. This review discusses their principles, possible pitfalls, and potential for a...

متن کامل

Quality Assessment in Apples Using Low Field Magnetic Resonance Imaging

Quality assessment in apples often requires the application of non destructive methods for detecting symptoms that are not visible externally. Various techniques such as NMR, MRI, Xray CT and time-resolved reflectance spectroscopy have been used to analyze the internal quality of fruits [1,2,3]. We report preliminary results showing that low field MRI has a potential for the internal quality in...

متن کامل

Low-Field Cardiac Magnetic Resonance Imaging

Cardiac magnetic resonance (CMR) is arguably unmatched in its ability to evaluate cardiovascular structure and function, to characterize myocardial tissue by a wide variety of mechanisms, and to quantitatively assess blood flow and perfusion without the use of radiation or the need for invasive catheterization. CMR research and development continues at a rapid pace both in academia and by comme...

متن کامل

Techniques and Bio-medical Applications of Field-cycling Magnetic Resonance

NMR relaxometry refers to the measurement of relaxation times (usually T1) as a function of magnetic field strength. It is usually accomplished using fast field-cycling (FFC), in which the magnetic field is switched rapidly between levels during the pulse sequence. By switching the magnetic field, the nuclear spins can “evolve” at a chosen magnetic field strength, after which the magnetic field...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics of Fluids

سال: 2021

ISSN: ['1527-2435', '1089-7666', '1070-6631']

DOI: https://doi.org/10.1063/5.0065986