LACRIMAL PRODUCTION OF CATS: SCHIRMER TEAR TEST, PHENOL RED THREAD TEAR TEST AND ENDODONTIC ABSORBENT PAPER POINT
نویسندگان
چکیده
منابع مشابه
Effect of acepromazine or xylazine on tear production as measured by Schirmer tear test in normal cats.
OBJECTIVE To evaluate the effect of acepromazine or xylazine on Schirmer tear test 1 results in clinically normal cats. ANIMALS Sixteen healthy cross-breed cats. PROCEDURE The animals were randomly divided into two groups of eight cats each. The first group was sedated with acepromazine alone (0.2 mg/kg) and the second group received only xylazine (2 mg/kg). All cats had Schirmer tear test ...
متن کاملEvaluation of Phenol Red Thread test versus Schirmer test in dry eyes: A comparative study
BACKGROUND Dry eye is the most common ocular morbidity found in elderly patients. There is no gold standard/standard test for diagnosing dry eye. OBJECTIVES The present study was conducted to compare the potential of Phenol Red Thread (PRT) test versus Schirmer Test in diagnosing dry eye. MATERIALS AND METHODS The study was conducted on 50 patients, aged 40 years and above. History of dry e...
متن کاملEffect of temperature and humidity in the Schirmer tear test.
THE Schirmer I tear test developed and standardized by Halberg and Berens, New York City (Contactisol Inc. Lindenhurst, N.Y.) is a useful screening procedure for keratoconjunctivitis sicca in large numbers of patients suffering from various connective tissue disorders. When all the patients attending a centre for rheumatic diseases were subjected to this test it was noted that a surprisingly hi...
متن کاملTear meniscus changes during cotton thread and Schirmer testing.
PURPOSE To elucidate the effect of the cotton thread test (CT-T) and Schirmer test (S-T) on the tear reservoir by evaluating the radius of tear meniscus curvature. METHODS The radii (R) of the central lower tear menisci were measured by a newly developed video meniscometer in 11 eyes of 11 normal volunteers (6 men, 5 women; mean age, 27.7 +/- 3.6 years [SD]) and 9 eyes of 9 patients with tear...
متن کاملThe tear film characteristics of spontaneous subconjunctival hemorrhage patients detected by Schirmer test I and tear interferometry
PURPOSE To evaluate the tear film characteristics of spontaneous subconjunctival hemorrhage patients by Schirmer test I and tear interferometry. METHODS Forty-six spontaneous subconjunctival hemorrhage patients and 46 controls were enrolled in the study. Schirmer test I and tear interferometry were performed in all 92 subjects. The results obtained were compared between the two groups. RESU...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Enciclopédia Biosfera
سال: 2015
ISSN: 1809-0583,2317-2606
DOI: 10.18677/enciclopedia_biosfera_2015_182