L X-ray spectrometry in vivo with a Si(Li)-NaI(Tl) detector
نویسندگان
چکیده
منابع مشابه
Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملDetermining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry
The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method, and the formation of beads. Certified reference bauxite samples were used for the cali...
متن کاملHigh-pressure operation of a xenon-GPSC/MSGC hybrid detector for hard X-ray spectrometry
The performance of a high-pressure xenon gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector has been investigated for filling pressures from 1 up to 10 bar, for 22-, 30and 60-keV photons. GPSC/MSGC hybrid detectors are based on a xenon-GPSC instrumented with a CsI-coated microstrip plate photosensor placed directly within the xenon envelope, as a substitut...
متن کاملX-ray micro-CT with a displaced detector array.
Because the sizes of samples differ in x-ray micro-CT applications, it is desirable to have a mechanism to change the field of view of a micro-CT scanner. A well-known way to double the diameter of the field of view is to displace a detector array by 50%. In this paper, we propose to displace a detector array by an amount of greater than 0% but less than 50% for a continuously adjustable field ...
متن کاملX-Ray Imaging with a Silicon Microstrip Detector
A single photon counting X-ray imaging system, with possible applications to dual energy mammography and angiography, is presented. A silicon microstrip detector with 100 mm pitch strips is coupled to RX64 ASICs, each of them including 64 channels of preamplifier, shaper, discriminator and scaler. The system has low noise, good spatial resolution and high counting rate capability. Results on en...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1990
ISSN: 0018-9499,1558-1578
DOI: 10.1109/23.106727