Known Addition Procedure for Determining Fluoride in Feeds with an Ion-Specific Electrode

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of fluoride in wine by fluoride selective ion electrode, standard addition method: collaborative study.

The accuracy, precision, and reproducibility of a rapid method for determination of fluoride in wine, using a fluoride selective ion electrode, were established by a collaborative study involving 12 laboratories, 5 in Europe and 7 in the United States. The laboratories assayed 6 Youden pairs of fluoride-fortified, red and white wine samples with fluoride concentrations ranging from 0.2 to 3.0 m...

متن کامل

Measurements with fluoride ion selective electrode

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...

متن کامل

Validation of an ion selective electrode system for the analysis of serum fluoride ion

A high impedance unit was developed for use with a fluoride/pH electrode system for the measurement of serum fluoride. The linearity, accuracy, precision and detection limit of the system is reported. At a pH of 1.55, the system was linear over a range of serum fluoride concentrations up to 100 mumol l(-1), with a lower limit of detection of 0.3 mumol l(-1). Recoveries at this pH were 94-105% i...

متن کامل

Micromethod for determining plasma ammonia nitrogen with use of an ion-selective electrode.

A micromethod for measuring the ammonia nitrogen content of plasma by use of an ion-selective electrode is evaluated and described. The effect of storing plasma for 24, 48, and 72 h at -70 degrees C was evaluated. Values for newborns and fasting adults were 880 micrograms/L (SD, 210 micrograms/L) and 620 micrograms/L (SD, 170 micrograms/L), respectively.

متن کامل

An electrode immobilized in a graphite matrix with ion pair complex for the determination of diclofenac in pharmaceuticals

A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of AOAC INTERNATIONAL

سال: 1974

ISSN: 0004-5756

DOI: 10.1093/jaoac/57.3.508