Kinetics of Ethanol Oxidation in High-Pressure Steam
نویسندگان
چکیده
منابع مشابه
Kinetics of Ethanol Oxidation in High-Pressure Steam*
Ethanol oxidation rate in high pressure steam at the pressure of 10 MPa in the temperature ranging from 430 to 490 °C was studied with the fuel equivalence ratio of 0.4. On the assumption that the reaction order is first order, the reaction rate parameters obtained in the experiments are 10 ± 0.4 s for the pre-exponential factor and 166.5 ± 6.1 kJ·mol for the activation energy. This ethanol oxi...
متن کاملChemical Kinetics of Ethanol Oxidation
Experimental profiles of stable species mole fractions are reported for ethanol oxidation in a Variable Pressure Flow Reactor (VPFR) at initial temperatures of 800-950K and constant pressures of 3 to 12atm. A detailed mechanism for ethanol combustion is developed in a hierarchical manner, and at each level, the newly added portions of the mechanism are tested by thorough comparison of model pre...
متن کاملSurvey on Prevacuum High-pressure Steam Sterilizers.
None of the 10 prevacuum high-pressure sterilizers of different makes tested was able to produce and maintain the conditions advocated by the Medical Research Council working party on high-pressure steam sterilizers (1959) or by Knox and Penikett (1958) with the result that steam did not penetrate adequately the single challenge load and it was not sterilized. The sterilization of ;group drums'...
متن کاملHigh Temperature Oxidation Kinetics of Dysprosium Particles
Rare earth elements have been recognized as critical materials for the advancement of many strategic and green technologies. Recently, the United States Department of Energy has invested many millions of dollars to enhance, protect, and forecast their production and management. The work presented here attempts to clarify the limited and contradictory literature on the oxidation behavior of the ...
متن کاملMonitoring sterilization of dressings in high-vacuum pressure-steam sterilizers.
Undetected air leaks in a high-vacuum sterilizer can defeat the sterilization process. For this reason the maintenance and supervision of these sterilizers needs expert engineering care. The importance of controlling the high-vacuum sterilization process from the centre of a load rather than the chamber drain is emphasized, and a method of detecting any failure in a high-vacuum process is descr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Thermal Science and Technology
سال: 2011
ISSN: 1880-5566
DOI: 10.1299/jtst.6.34