Design of a capillary viscometer with numerical and computational methods
A high temperature and shear rate capillary viscometer has been designed, constructed and recently commissioned. This device will be used to measure the viscosity of semi-solid metals under the high temperature and shear rate conditions, similar to those found in industry. Design criteria for the device included a requirement for a highly controllable temperature (±1oC) up to 650oC, capability ...
متن کاملAutomated measurement of plasma viscosity by capillary viscometer.
Plasma viscosity has several advantages over the erythrocyte sedimentation rate as a measurement of an acute phase response of more than 24 hours' duration. A new capillary viscometer (Coulter Viscometer II), which gives an automated measurement of plasma viscosity, was compared with the selected manual method (Harkness viscometer) of the International Committee for Standardization in Haematolo...
متن کاملAn atomic kinetic energy functional with full Weizsacker correction.
A functional is proposed for representing the electronic kinetic energy of the ground state of an N-electron atom or ion in terms of its electron density, [Formula: see text] Here T(w) is the Weizsacker quantity ((1/8))integral(nablarho.nablarho/rho)dtau and T(0) is the Thomas-Fermi quantity C(F) integral rho(5 / 3)dtau. From Hartree-Fock data on 55 neutral atoms, C = 1.412 +/- 0.033; for 1200 ...
متن کاملRole of Kinetic Energy
Peak systolic pulmonary valvar pressure gradients are frequently seen in large intracardiac left-to-right shunt lesions. Conventionally, this has been attributed to "relative" pulmonic stenosis. Theoretical considerations suggest that this gradient is due to differences in expression of the total fluid energy. The side pressure, the downstream pressure, the end pressure, and the flow velocity i...
متن کاملTwo-peak approximation in kinetic capillary electrophoresis.
Kinetic capillary electrophoresis (KCE) constitutes a toolset of homogeneous kinetic affinity methods for measuring rate constants of formation (k(+)) and dissociation (k(-)) of non-covalent biomolecular complexes, C, formed from two binding partners, A and B. A parameter-based approach of extracting k(+) and k(-) from KCE electropherograms relies on a small number of experimental parameters fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Society of Chemical Industry, Japan
سال: 1958
ISSN: 0023-2734,2185-0860
DOI: 10.1246/nikkashi1898.61.428