Kinetic-based determinations in continuous-flow analysis
نویسندگان
چکیده
منابع مشابه
Kinetic-based determinations in continuous-flow analysis
Introduction The automation ot analytical processes is becoming an increasingly important area in analytical chemistry and is a response to the growing complexity of the problems faced and to the need to cut down on expenses on
متن کاملKinetic parameters of continuous flow analysis.
Unlike systems of batch analysis, continuous flow systems possesskinetic parameters. Associated with the steady state are such measurements as noise level and drift. This study reports on kinetic parameters associated with the transient state between the steady states including time required to change from base-line steady state to sample steady state and vice versa, characteristics of this cha...
متن کاملAutomatic flow systems based on sequential injection analysis for routine determinations in wines
Sequential injection systems for wine analysis have been developed in recent years for determination of more than 20 species. Several aspects of these systems are reviewed in the present paper. Special focus is given to implementation of in-line sample treatment and adaptation of system operation through software control to enable determination in different types of wine. The strategies used to...
متن کاملKinetic Analysis of β-Galactosidase Activity using the PowerWaveTM HT and Gen5TM Data Analysis Software Basic enzyme kinetic determinations
Most biological processes require an enzyme to act as a catalyst in order for the reaction to take place. With the exception of catalytic RNA, all enzymes are proteins. Most importantly, enzymes are highly effective in catalyzing diverse chemical reactions in a regulated, selective, and specific manner. With a few exceptions, most reactions catalyzed by enzymes can be described satisfactorily b...
متن کاملImmobilized enzymes in continuous-flow analysis.
Glucose oxidase, uricase, and urease were immobilized on the interior surface of activated polyamide tubing. The shelf-life of such enzyme bearing tubes was at least six months. The tubes were used for continuous-flow analysis of glucose, uric acid, and urea with conventional systems and with hybrid micro-scale systems in which modules of different manufacture were combined. The length of enzym...