Kinetic analysis of ion incident angle distribution on a plasma-facing wall
نویسندگان
چکیده
منابع مشابه
POD analysis of flow over a backward-facing step forced by right-angle-shaped plasma actuator
PURPOSE This study aims to present flow control over the backward-facing step with specially designed right-angle-shaped plasma actuator and analyzed the influence of various scales of flow structures on the Reynolds stress through snapshot proper orthogonal decomposition (POD). METHODS 2D particle image velocimetry measurements were conducted on region (x/h = 0-2.25) and reattachment zone in...
متن کاملfabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions
a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...
Instability of ion kinetic waves in a weakly ionized plasma.
The fundamental higher-order Landau plasma modes are known to be generally heavily damped. We show that these modes for the ion component in a weakly ionized plasma can be substantially modified by ion-neutral collisions and a dc electric field driving ion flow so that some of them can become unstable. This instability is expected to naturally occur in presheaths of gas discharges at sufficient...
متن کاملEffect of high-flux, low-energy He+ ion irradiation on Ta as a plasma-facing material
The goal of this work is to assess Ta as a potential plasma-facing material for future fusion reactors in terms of its response to high-flux, low-energy He+ ion irradiation. Ta samples were irradiated with 100 eV He+ ions at various fluences up to 3.5 × 1025 ions m-2 while simultaneously heated at constant temperatures in the range 823-1223 K. SEM studies show that irradiated Ta surfaces underg...
متن کاملComparative Study of Anchored Wall Performance with Two Facing Designs
The present study compared the performance of soldier pile and concrete bearing pad anchored wall facings. Using Abaqus finite element software, two case studies have been precisely represented for the facing designs and effects of the parameters of soil type, spacing of anchors and facings, surcharge and facing sizes were investigated. The analysis results indicate that the soldier pile method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Nuclear Materials
سال: 2009
ISSN: 0022-3115
DOI: 10.1016/j.jnucmat.2009.01.160