Kilovoltage x-ray dosimetry—an experimental comparison between different dosimetry protocols
نویسندگان
چکیده
منابع مشابه
Advances in kilovoltage x-ray beam dosimetry.
This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage...
متن کاملDosimetry of Occupational Radiation around Panoramic X-ray Apparatus
Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).<br ...
متن کاملComparison of kilovoltage x-ray and electron beam dose distributions for radiotherapy of the sternum.
The dose distributions for a patient with cancer involving the sternum were calculated for both a kilovoltage x-ray beam and a megavoltage electron beam. The minimum target dose and dose uniformity over the target volume were significantly better using electrons (90%-101%) than kilovoltage x-rays (68%-119%). The calculated lung dose and integral patient dose were also less for electrons than ki...
متن کاملMethod comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting.
Several measurement techniques have been developed to address the capability for target volume reduction via target localization in image-guided radiotherapy; among these have been ultrasound (US) and fiducial marker (FM) software-assisted localization. In order to assess interchangeability between methods, US and FM localization were compared using established techniques for determination of a...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics in Medicine and Biology
سال: 2008
ISSN: 0031-9155,1361-6560
DOI: 10.1088/0031-9155/53/16/014