منابع مشابه
Have You Tested Your Goldmann Tonometer Today?
Intraocular pressure (IOP) is the only known modifiable risk factor for glaucoma. Besides being a cornerstone in glaucoma management, accurate measurement of IOP forms an important component of routine ophthalmic evaluation. Despite the innovation of various newer tonometers, Goldmann applanation tonometer is still considered the Gold standard for IOP measurement. However, there are several rep...
متن کاملGoldmann tonometer error correcting prism: clinical evaluation
PURPOSE Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. METHODS A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness,...
متن کاملComparison of the iCare rebound tonometer and the Goldmann applanation tonometer
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the res...
متن کاملClinical comparison of the Icare tonometer and Goldmann applanation tonometry.
PURPOSE To compare a new method of intraocular pressure (IOP) measurement, using the Icare tonometer, with Goldmann applanation tonometry (GAT). PATIENTS AND METHODS Two observers obtained IOP readings in 292 eyes (143 right and 149 left) of 153 subjects, using the Icare without topical anesthetic. A GAT reading was subsequently obtained by a consultant ophthalmologist, without the knowledge ...
متن کاملComparison of the CT80 Non-Contact Tonometer and Goldmann Applanation Tonometer
Aim of Study: To compare the intraocular pressure (IOP) measurements obtained with the computerized tonometer 80 non-contact tonometer (CT80 NCT) and those with the Goldmann applanation tonometer (GAT) in patients with normal and high IOP. Patients and Methods: This observational clinical study comprised 187 eyes of 105 patients (54 men and 51 women), who had their IOP readings measured with bo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 1993
ISSN: 0950-222X,1476-5454