K-factor image deshadowing for three-dimensional fluorescence microscopy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

K-factor image deshadowing for three-dimensional fluorescence microscopy

The ability to track single fluorescent particles within a three dimensional (3D) cellular environment can provide valuable insights into cellular processes. In this paper, we present a modified nonlinear image decomposition technique called K-factor that reshapes the 3D point spread function (PSF) of an XYZ image stack into a narrow Gaussian profile. The method increases localization accuracy ...

متن کامل

Improved localization accuracy in stochastic super-resolution fluorescence microscopy by K-factor image deshadowing.

Localization of a single fluorescent particle with sub-diffraction-limit accuracy is a key merit in localization microscopy. Existing methods such as photoactivated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM) achieve localization accuracies of single emitters that can reach an order of magnitude lower than the conventional resolving capabilities of op...

متن کامل

Three dimensional image restoration in fluorescence lifetime imaging microscopy.

A microscope set-up and numerical methods are described which enable the measurement and reconstruction of three-dimensional nanosecond fluorescence lifetime images in every voxel. The frequency domain fluorescence lifetime imaging microscope (FLIM) utilizes phase detection of high-frequency modulated light by homodyne mixing on a microchannel plate image intensifier. The output signal at the i...

متن کامل

Three-dimensional holographic fluorescence microscopy.

Most commonly used methods for three-dimensional (3D) fluorescence microscopy make use of sectioning techniques that require that the object be physically scanned in a series of two-dimensional (2D) sections along the z axis. The main drawback in these approaches is the need for these sequential 2D scans. An alternative approach to fluorescence imaging in three dimensions has been developed tha...

متن کامل

Evaluating performance in three-dimensional fluorescence microscopy

In biological fluorescence microscopy, image contrast is often degraded by a high background arising from out of focus regions of the specimen. This background can be greatly reduced or eliminated by several modes of thick specimen microscopy, including techniques such as 3-D deconvolution and confocal. There has been a great deal of interest and some confusion about which of these methods is '...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scientific Reports

سال: 2015

ISSN: 2045-2322

DOI: 10.1038/srep13724