JAMINAN MUTU PESAWAT CT SCAN SINGLE SLICE DI UNIT RADIOLOGI RSU SEMARA RATIH

نویسندگان

چکیده

Latar Belakang: Pesawat CT Scan single slice Merk SIEMENS/Dura 302 MV di unit Radiologi Rumah Sakit Umum Semara Ratih Kabupaten Tabanan Bali terpasang pada bulan Nopember 2020 merupakan alat second hand dengan tahun produksi 2012. Pelaksanaan kendali dilakukan saat penerimaan (acceptance test) meliputi pengujian terhadap indeks dosis (CTDI) untuk kepala, (CTDI badan, CT-Number udara, kesesuaian table setting semua slice, indikator posisi meja (sumbu z), laser penanda dan april 2021 yang oleh Badan Pengawas Fasilitas Kesehatan (BPFK) Surabaya uji teknis generator tabung sinar-X (uji akurasi tegangan tabung, kualitas berkas sinar-X), citra number air, keseragaman number), pelaksanaan mutu rutin peralatan radiologi jarang dilaksanakan secara berkesinambungan menjaga kinerja pesawat Scan. Metode penelitian: kualitatif deskriptif pendekatan survey. Hasil Pembahasan: Pengujian telah diperoleh nilai rata water phantom lima berbeda adalah -1,68; -0,76; -2,21; -1,77; -1,53 HU berada rentang toleransinya yaitu -4 sampai 4 HU. Dry printer hasil sebagaian besar masih sesuai parameter berlaku, hanya pattern 0% terdapat melebihi standar artinya quality control Unit RSU tidak sasuai sehingga perlukan kalibrasi. Pada form check list mengetahui ada nya tombol berfungsi fungsi berfungi baik. Kesimpulan: dalam batas normal kecuali dry printer.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-slice helical CT: scan and reconstruction.

The multi-slice CT scanner refers to a special CT system equipped with a multiple-row detector array to simultaneously collect data at different slice locations. The multi-slice CT scanner has the capability of rapidly scanning large longitudinal (z) volume with high z-axis resolution. It also presents new challenges and new characteristics. In this paper, we study the scan and reconstruction p...

متن کامل

Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

متن کامل

64-slice CT scan in Kathmandu Medical College Teaching Hospital.

64-slice CT scan is a versatile newly introduced imaging technology, which is capable of diagnosing various diseases from head to toe. The 64-slice CT coronary angiography has a negative predictive value of 100%. Virtual images of bronchi, stomach and colon can provide definite diagnosis. Coronary artery calcification score which predicts coronary artery disease can be calculated by 64-slice CT...

متن کامل

A Hybrid Method for Segmentation and Visualization of Teeth in Multi-Slice CT scan Images

Introduction: Various computer assisted medical procedures such as dental implant, orthodontic planning, face, jaw and cosmetic surgeries require automatic quantification and volumetric visualization of teeth. In this regard, segmentation is a major step. Material and Methods: In this paper, inspired by our previous experiences and considering the anatomical knowledge of teeth and jaws, we prop...

متن کامل

External radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans

Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...