منابع مشابه
Comparison of bupivacaine and bupivacaine with fentanyl in continuous extradural analgesia during labour.
In a randomized, double-blind study of 39 mothers in labour, we have compared a loading dose of 0.5% bupivacaine 6.0 ml and fentanyl 100 micrograms given extradurally, followed by an infusion of 0.08% bupivacaine 15 ml h-1 plus fentanyl 37.5 micrograms h-1, with a loading dose of 0.5% bupivacaine 6.0 ml and saline 2.0 ml, followed by an extradural infusion of 0.08% bupivacaine alone, per hour. ...
متن کاملIntrathecal ropivacaine or bupivacaine with fentanyl for labour.
Combined spinal-epidural (CSE) is widely used to provide pain relief in labour while minimizing motor blockade. Aiming to further reduce associated motor weakness, we compared ropivacaine 2.5 mg in the intrathecal injection with a standard bupivacaine CSE in a double-blind study. Forty women were randomized to receive either bupivacaine 2.5 mg or ropivacaine 2.5 mg intrathecally, both with fent...
متن کاملStroke Mimic Secondary to IV Fentanyl Administration.
Fentanyl is a potent opioid used commonly in acute care because of its rapid onset and short duration of action. It has fewer side effects when compared with commonly available opioids, such as morphine and hydromorphine. We report an unusual side effect of transient aphasia following fentanyl administration. A 61-year-old female presented for an elective embolization of a periophthalmic artery...
متن کاملCardiopulmonary Collapse during Labour
Cardiopulmonary collapse during labour is a catastrophic event caused by various medical, surgical and obstetrical conditions. It is an emergency that threatens the life of the mother and her unborn child. We present a case of a pregnant woman who suffered from preeclampsia and underwent induction of labour. Severe lung edema occurred early in labour that caused cardiopulmonary collapse. Advanc...
متن کاملCardiac output during labour.
Serial measurements of cardiac output and mean arterial pressure were performed in 15 women during the first stage of labour and at one and 24 hours after delivery. Cardiac output was measured by Doppler and cross sectional echocardiography at the pulmonary valve. Basal cardiac output (between uterine contractions) increased from a prelabour mean of 6.99 l/min to 7.88 l/min at greater than or e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anaesthesia
سال: 1992
ISSN: 0832-610X,1496-8975
DOI: 10.1007/bf03008383