Iterative correction of beam hardening artifacts in CT.

PURPOSE To reduce beam hardening artifacts in CT in case of an unknown x-ray spectrum and unknown material properties. METHODS The authors assume that the object can be segmented into a few materials with different attenuation coefficients, and parameterize the spectrum using a small number of energy bins. The corresponding unknown spectrum parameters and material attenuation values are estim...

متن کامل

An iterative approach to the beam hardening correction in cone beam CT.

In computed tomography (CT), the beam hardening effect has been known to be one of the major sources of deterministic error that leads to inaccuracy and artifact in the reconstructed images. Because of the polychromatic nature of the x-ray source used in CT and the energy-dependent attenuation of most materials, Beer's law no longer holds. As a result, errors are present in the acquired line in...

متن کامل

Automatic Beam Hardening Correction For CT Reconstruction

In computed tomography (CT) the quality of reconstructed images depends on several reasons: the quality of the set-up calibration; precision of the mathematical model, used in the reconstruction procedure; the reconstruction technique used; quality of the numerical implementation of the reconstruction algorithm. Most of fast reconstruction algorithms use the X-ray monochromaticity assumption. I...

متن کامل

Iterative Beam Hardening Correction for Multi-Material Objects

In this paper, we propose an iterative beam hardening correction method that is applicable for the case with multiple materials. By assuming that the materials composing scanned object are known and that they are distinguishable by their linear attenuation coefficients at some given energy, the beam hardening correction problem is converted into a nonlinear system problem, which is then solved ...

متن کامل

Expert-guided CT beam hardening correction for heterogeneous natural materials

We present a new method for correcting beam hardening artifacts in CT data. Software correction typically consists of a polynomial transform of the raw data, but determining optimal coefficients is not straightforward, especially if the material is not well known or characterized, as is the usual case when imaging geological materials. Our method lets an expert user guide an iterative optimizat...