Isozyme analysis of Plasmopara halstedii using cellulose-acetate gel electrophoresis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Haemoglobin electrophoresis on cellulose acetate using whole blood samples.

A modification of the method of haemoglobin electrophoresis using cellulose acetate membrane described by Kohn (1969) enables whole blood to be applied direct to the membrane instead of a haemolysate. The method gives results which are indistinguishable from those obtained using a haemolysate. Normal protein stains are not recommended, because of interference from plasma proteins, but the metho...

متن کامل

A quantitative method for blood lipoproteins using cellulose acetate electrophoresis.

A rapid, inexpensive, and quantitative method is described for obtaining the levels of plasma very low, low, and high density lipoproteins using cellulose acetate electrophoresis and lipid assays without prior separation by ultracentrifuge or other techniques. It involves separation of the lipoproteins by cellulose acetate electrophoresis, followed by their identification with the ozone-Schiff ...

متن کامل

Rapid cellulose acetate electrophoresis. I. Serum proteins.

A method of electrophoresis utilizing cellulose acetate is described wherein quantitation of serum protein fractions by densitometry is accomplished within 2 hr. of initiation of the procedure. The densitometer was found to have a linear response to amido black dye. Albumin and y-globulin demonstrated equal dye-binding characteristics. Combined with the absence of albumin trailing, this has aff...

متن کامل

Prediction of immunoglobulins from patterns of cellulose acetate electrophoresis.

The concentrations of serum immunoglobulins (Ig) C, A, and M were correlated with specific features in the $y region of densitometer patterns of serum protein electrophoresis on cellulose acetate membranes; visual analysis of densitometer patterns permitted semiquantitative prediction of values for lgC and lgA. Important immunoglobulin abnormalities, particularly elevations of IgA, were seen in...

متن کامل

Rapid electrophoresis and quantitation of haemoglobins on cellulose acetate.

A rapid and reproducible electrophoretic method for the separation and quantitation of haemoglobins on cellulose acetate is described. The accuracy of the method and its possible sources of error are discussed. The normal range for haemoglobin A(2) by this method is 1% to 3% of the total haemoglobin concentration. Blood samples from 32 thalassaemic patients showed haemoglobin A(2) values of 3.5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Plant Pathology

سال: 2007

ISSN: 0032-0862,1365-3059

DOI: 10.1111/j.1365-3059.2007.01737.x