Isolation of <i>Legionella pneumophila</i> from the UOEH Cooling Tower

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation of Legionella pneumophilia from cooling tower water by filtration.

Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.

متن کامل

Negative enrichment procedure for isolation of Legionella pneumophila from seeded cooling tower water.

A negative enrichment procedure was developed which was capable of isolating Legionella pneumophila directly from seeded air-conditioning cooling tower water onto laboratory media. This procedure was based on an 8-h incubation under conditions that were bactericidal to the indigenous water microflora but merely bacteriostatic to L. pneumophila.

متن کامل

Improved facility and sensitivity in the use of guinea pigs for the isolation of Legionella pneumophila from cooling tower water.

The established criteria for the determination of the optimum time for the sacrifice of guinea pigs inoculated with samples of cooling tower water were found to be inadequate for the detection of low levels of Legionella pneumophila. By ignoring the requirement for fever and by sequentially sacrificing the infected guinea pigs on days 3 through 5 postinoculation, we simplified the procedure, an...

متن کامل

the effect of traffic density on the accident externality from driving the case study of tehran

در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...

15 صفحه اول

Snowfall observations from natural-draft cooling tower plumes.

During the winter of 1975-1976, snowfall from the plumes of large natural-draft cooling towers of power plants has been observed. Snow accumulations up to 2.5 centimeters have been found on the ground at extended distances from the cooling towers, and visibility has been restricted to less than 1600 meters in the tower plume near ground level.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of UOEH

سال: 1986

ISSN: 0387-821X,2187-2864

DOI: 10.7888/juoeh.8.423