Isolated pulse oximetry readings are unreliable
نویسندگان
چکیده
منابع مشابه
Effects of intravenously administered indocyanine green on near-infrared cerebral oximetry and pulse oximetry readings
BACKGROUND Intravenously administered indocyanine green (ICG) may cause misreadings of cerebral oximetry and pulse oximetry in patients undergoing carotid endarterectomy under general anesthesia. The present study determined the effects of two different doses (12.5 mg vs. 25 mg) of ICG on regional cerebral tissue oxygen saturation (SctO2) and percutaneous peripheral oxygen saturation (SpO2). ...
متن کاملPulse Oximetry
The principal advantage of optical sensors for medical applications is their intrinsic safety since there is no electrical contact between the patient and the equipment. (An added bonus is that they are also less suspect to electromagnetic interference). This has given rise to a variety of optical techniques to monitor physiological parameters: for example, the technique of Laser Doppler veloci...
متن کاملPulse Oximetry
Introduction There is no doubt that pulse oximetry represents the greatest advance in patient monitoring in many years. It has the unique advantage of continuously monitoring the saturation of hemoglobin with oxygen, easily and noninvasively, providing a measure of cardio-respiratory function. By virtue of its ability to quickly detect hypoxaemia, it has become the standard of care during anaes...
متن کاملForehead pulse oximetry: Headband use helps alleviate false low readings likely related to venous pulsation artifact.
BACKGROUND This study investigated whether a tensioning headband that applies up to 20 mmHg pressure over a forehead pulse oximetry sensor could improve arterial hemoglobin oxygen saturation reading accuracy in presence of venous pooling and pulsations at the forehead site. METHODS Healthy volunteers were studied breathing room air in supine and various levels of negative incline (Trendelenbu...
متن کاملEffect of hemiparetic stroke on pulse oximetry readings on the affected side.
BACKGROUND AND PURPOSE Hypoxia is common after stroke, and monitoring by pulse oximetry is suggested in the acute phase. Physical changes on the affected side or intravenous infusions may affect oximeter readings. This study was designed to test whether pulse oximetry recordings are the same on the affected and nonaffected sides in stroke patients. METHODS Oxygen saturation (SpO(2)) and heart...