Isoelectric Focusing Sample Injection for Capillary Zone Electrophoresis in a Fused Silica Capillary
نویسندگان
چکیده
منابع مشابه
Isoelectric focusing sample injection for capillary zone electrophoresis in a fused silica capillary.
An improvement has been made to couple isoelectric focusing (IEF) sample injection and capillary zone electrophoresis in an untreated fused silica capillary. Electroosmotic flow is efficiently prevented by simply using a rubber block at the outlet end of the capillary during IEF sample injection. The experimental conditions that affect the concentration effect are discussed. A concentration enh...
متن کاملTwo-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.
CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo...
متن کاملCapillary Isoelectric Focusing
Beale SC (1998) Capillary electrophoresis. Analytical Chemistry 70: 279. (This journal prints every two years a review on capillary electrophoresis. The article is written by an expert in the Reld and covers more or less all developments in CE including CGE of the preceding years.) Grossmann PD and Colburn JC (eds) (1996) Capillary Electrophoresis: Theory and Practice. San Diego: Academic Press...
متن کاملWhole-Column-Imaging Detection for Capillary Isoelectric Focusing and Capillary Electrophoresis
Despite the significant advantages of capillary isoelectric focusing over gel isoelectric focusing, widespread acceptance of the technique as a replacement for gel isoelectric focusing has not occurred. Several factors contribute to capillary isoelectric focusing’s slower-than-expected adoption; perhaps the most important are the performance and procedural difficulties introduced when capillary...
متن کاملCapillary isoelectric focusing after sample enrichment with immunoaffinity chromatography in a single capillary
For accurate micro-scale quantification of a specific protein in biological fluids, immunoaffinity chromatography (IAC) and isoelectric focusing (IEF) were combined in a single fused-silica capillary. The inner wall of the capillary was coated with an anti-E-tag antibody at the inlet side to form an IAC column, and polydimethylacrylamide, a neutral polymer, at the outlet side to form the capill...