Isocratic High-Performance Liquid Chromatographic Assay of Olanzapine: Method Development and Validation
نویسندگان
چکیده
منابع مشابه
Development and Validation of Reversed-Phase High Performance Liquid Chromatographic Method for Hydroxychloroquine Sulphate
In the present work new, simple reversed-phase high performance liquid chromatographic method was developed and validated for the determination of hydroxychloroquine sulphate in blood plasma. Chloroquine sulphate was used as an internal standard. The chromatographic separation was achieved with octadecyl silane Hypersil C18 column (250×6 mm, 5 μm) using water and organic (acetonitrile:methanol:...
متن کاملDevelopment and Validation of a Specific Stability Indicating High Performance Liquid Chromatographic Method for Valsartan
A stability-indicating HPLC assay method has been developed and validated for valsartan in bulk drug and pharmaceutical dosage forms. An isocratic RP-HPLC was achieved on Waters 2695 using Symmetry C18 (250mm × 4.6mm × 5μ) column with the mobile phase consisting of 0.02 mM sodium dihydrogen ortho-phosphate, pH adjusted to 2.5 using ortho-phosphoric acid (solvent A), and acetonitrile (solvent B)...
متن کاملHigh Performance Liquid Chromatographic Method Development and its Validation for Lacidipine
A simple and sensitive high performance liquid chromatographic (HPLC) method was developed for quantification of lacidipine in human plasma. Felodipine was used as an internal standard (IS). The present method used protein precipitating extraction of lacidipine from plasma. Separation was carried out on reversedphase c18 column (250 mm × 4.6 mm, 5μ) and the column effluent was monitored by UV d...
متن کاملA High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma
A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...
متن کاملValidation of high-performance liquid chromatographic method for analysis of fluconazole in microemulsions and liquid crystals
In recent decades, there has been a significant increase in the incidence of fungal diseases. Certain fungal diseases cause cutaneous lesions and in the usual treatment, generally administred orally, the drug reaches the site of action with difficulty and its concentration is too low. An approach much explored in recent years is the development of nanotechnology-based drug delivery systems, and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ISRN Analytical Chemistry
سال: 2014
ISSN: 2090-732X
DOI: 10.1155/2014/616941