After large-scale photovoltaic (PV) and wind power integration with the national grid, island grid detection is a crucial technique that identifies when should be considered as dead. This logic built in an IEC61850 controller which mainly depends on bus bar scheme fault type. It becomes more complex ½ circuit breaker utilized. The lack of communication redundancy causes mal-operation due to substation's DC supply failure. In order avoid such discrepancies, this paper investigates conventional islanding method. Then, advanced 2oo3 architecture proposed for detection, based SAS redundant improves reliability. However, even if there interface failure, plant control center can still detect through SCADA IEC60870-5-101/104 gateways integration. method has tendency full supervision entire perfect logical judgment by operation staff. feasible play decisive role system network stability blackout.
منابع مشابه
hydrochlorothiazide detection in urine samples by hplc-dad and experimental design dispersive l-l microextraction
hydrochlorothiazide (hct) is a diuretic agent which is shown to be effective in the treatment of hypertension. literature reports have demonstrated that urinary excretion data may be used to assess the bioavailability of various formulations containing this thiazide. also hct consumption by the athletes is one of the drugs which should be regulated by world anti-doping agency (wada), because of...
The Use of Triple-Modular Redundancy to Improve Computer Reliability
One of the proposed techniques for meeting the severe reliability requirements inherent in certain future computer applications i s described. This technique involves the use of triple-modular redundancy, which is essentially the use of the two-out-of-three voting concept at a low level. Effects of imperfect votingcircuitryand ofvarious interconnectionsof logical elementsareassessed. A hypothet...
متن کاملControl of DVR by Fuzzy Controller to Improve Voltage in Distribution System
With the development of critical loads, power quality problem has become particularly important and poor power quality will be cause many adverse effects and the cost of many deaths will follow. To improve power quality and protection of sensitive loads against grid disturbances have been used new equipment based on power electronics similar FACTs devices, they are Custom Power. One of the most...
متن کاملAn Advanced Hysteresis Controller to Improve Voltage Profile of Power System with PV Units: A Smart Grid Power Exchange Framework
Unlike traditional power grids, smart grids have the advantage of bidirectional power flow and having distributed generations. Distributed generation systems are usually supplied by renewable sources which can cause unpredicted voltage fluctuations as a result of being intermittent. While traditional compensating devices deal with the problem of voltage fluctuation and reduced power quality wit...
متن کاملEvaluation of Reliability Parameters in Micro-grid
Evaluation of the reliability parameters in micro-grids based on renewable energy sources is one of the main problems that are investigated in this paper. Renewable energy sources such as solar and wind energy, battery as an energy storage system and fuel cell as a backup system are used to provide power to the electrical loads of the micro-grid. Loads in the micro-grid consist of interruptible...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering, Technology & Applied Science Research
سال: 2021
ISSN: ['1792-8036', '2241-4487']
DOI: https://doi.org/10.48084/etasr.4035