Is cementing technique the cause of early aseptic loosening of the tibial component in total knee arthroplasty? A report of 22 failed tibial components
نویسندگان
چکیده
منابع مشابه
Tibial component rotation in total knee arthroplasty
BACKGROUND Both the range of motion (ROM) technique and the tibial tubercle landmark (TTL) technique are frequently used to align the tibial component into proper rotational position during total knee arthroplasty (TKA). The aim of the study was to assess the intra-operative differences in tibial rotation position during computer-navigated primary TKA using either the TTL or ROM techniques. The...
متن کاملSymptomatic loosening of a total knee arthroplasty caused by a tibial chondrosarcoma – a case report
Premature implant loosening following total knee arthroplasty (TKA) can have several causes. In this article we report on a rare case of a 74 year old male patient suffering tibial component loosening 14 month after primary TKA. The patient did neither have any malignancies nor joint arthroplasty before. Upon clinical examination the range of motion in the diseased knee was painfully restricted...
متن کاملThe all-polyethylene tibial component in primary total knee arthroplasty.
Outcomes of total knee arthroplasties performed with modern all-polyethylene tibial components have been found to be comparable with or better than those of arthroplasties done with metal-backed modular components in numerous mid-to-long-term follow-up studies, radiostereometric analyses, and the few prospective randomized trials available. Advantages of an all-polyethylene tibial component ove...
متن کاملConversion Total Knee Arthroplasty after Failed High Tibial Osteotomy
Clinical results of high tibial osteotomy (HTO) deteriorate over time despite the initial satisfactory results. Several knees may require a conversion to total knee arthroplasty (TKA) because of failure such as the progression of degenerative osteoarthritis and the loss of the correction angle. It is important to know the long-term survival rate and common reason of failure in HTO to inform pat...
متن کاملFracture of the Tibial Component in Total Knee Arthroplasty: Report on Two Cases
The authors report the rare occurrence of two cases of fracture of the tibial component in total knee arthroplasty. They review the literature and discuss the main factors that can cause failure of the implants.