IR Thermal Imaging Device using Photo-Patternable Temperature Sensitive Paint
نویسندگان
چکیده
منابع مشابه
Lock-in thermal IR imaging using a solid immersion lens
A hemispherical silicon solid immersion lens (SIL) was used to improve the spatial resolution of front-side thermal IR imaging in lock-in mode. The bottom of the SIL was cone-shaped to reduce the footprint of the SIL to the size of the imaged region. Caused by the lock-in operation mode, the detection limit improves by 2-3 orders of magnitude, and scattered light does not limit the image contra...
متن کاملThermal Forecasting Ability of Temperature-Sensitive Tracers
The development of a reliable and accurate method to predict thermal breakthrough time is a significant open problem in geothermal reservoir engineering. Such a method would enable more informed decisions to be made regarding reservoir management. Methods developed at present include analytical models and solute tracers, both of which have limitations. The use of particles as temperaturesensiti...
متن کاملAccuracy of Pressure Sensitive Paint
Uncertainty in pressure sensitive paint (PSP) measurement is investigated from a standpoint of system modeling. A functional relation between the imaging system output and luminescent emission from PSP is obtained based on studies of radiative energy transports in PSP and photodetector response to luminescence. This relation provides insights into physical origins of various elemental error sou...
متن کاملStudy of Trailing-Edge Cooling Using Pressure Sensitive Paint Technique
An experimental investigation was conducted to study the effects of blowing ratio and the existence of lands on the film cooling effectiveness of a turbine blade trailing-edge model. Instead of using a temperature-based technique, a mass transfer analogywas used to quantify the film cooling effectiveness. This was done through themeasurement of the distribution of oxygen concentration over the ...
متن کاملHighly sensitive detection of cancer cells using femtosecond dual-wavelength near-IR two-photon imaging
We describe novel imaging protocols that allow detection of small cancer cell colonies deep inside tissue phantoms with high sensitivity and specificity. We compare fluorescence excited in Styryl-9M molecules by femtosecond pulses at near IR wavelengths, where Styryl-9M shows the largest dependence of the two-photon absorption (2PA) cross section on the local environment. We show that by calcul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2014
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/557/1/012066