IQVision: An Image-Based Evaluation Tool for Quantitative Lateral Flow Immunoassay Kits
نویسندگان
چکیده
منابع مشابه
An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen
We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM) to quantify paramagnetic particles (PMPs) in immunochromatographic (lateral flow) assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA) in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinicall...
متن کاملEvaluation of lateral-flow Clostridium botulinum neurotoxin detection kits for food analysis.
The suitability and sensitivity of two in vitro lateral-flow assays for detecting Clostridium botulinum neurotoxins (BoNTs) in an assortment of foods were evaluated. Toxin extraction and preparation methods for various liquid, solid, and high-fat-content foods were developed. The lateral-flow assays, one developed by the Naval Medical Research Center (Silver Spring, MD) and the other by Alexete...
متن کاملLateral flow immunoassay for quantitative detection of ractopamine in swine urine.
A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT) to that of the control line (AC) was used to effectively minimize interference among strips and sample variations. The linear range for the quantitative detection of RAC was 0.2 ng/mL to ...
متن کاملDevelopment of a quantitative lateral flow immunoassay for the detection of aflatoxins in maize.
An immunoassay-based lateral flow device for the quantitative determination of four major aflatoxins in maize has been developed. The one-step assay has performance comparably with that of other screening methods, as confirmed by the intra- and the inter-day precision of the data (RSD 10-22%), and can be completed in 10 min. Quantification was obtained by acquiring images of the strip and corre...
متن کاملA Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate
A novel lateral flow immunoassay (LFIA) signal amplification strategy for the detection of Cry1Ab based on amplification via a polylysine (PL) chain and biotin-streptavidin system (BSAS) is described. In this system, multiple fluorescence dyes (FL) were directly coated on the surface of PL and conjugated with antibody via the BSAS for construction of novel signal amplification (FLPL-BSAS-mAb1) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biosensors
سال: 2021
ISSN: 2079-6374