IP-FCM: Immunoprecipitation Detected by Flow Cytometry
نویسندگان
چکیده
منابع مشابه
Biphenotypic hybrid acute leukaemia detected by two colour flow cytometry.
Immunophenotypic studies using immunofluorescent flow cytometry were performed on the blast cells of 36 patients with acute leukaemia using a panel of eight monoclonal antibodies. Six patients had blasts which co-expressed markers for lymphoid and myeloid differentiation, and which were therefore defined as biphenotypic hybrid acute leukaemia. Of the six, three patients were in the paediatric a...
متن کاملAutomated sperm concentration analysis with a new flow cytometry-based device, S-FCM.
The S-FCM uses flow cytometry technology to measure sperm concentrations. Semen samples from 104 men attending a male infertility clinic were used to evaluate the reproducibility of results and the carryover rate with the S-FCM by performing between- and within-run imprecision analyses. In addition, sperm concentrations measured with the S-FCM were compared with those obtained by manual analyse...
متن کاملFunctional Assays by Flow Cytometry
Cell function assays have been redefined over the past several years, largely because of technologies such as flow cytometry. The major difference between other techniques and those proposed using flow cytometry is the ability to analyze viable, single cells in a rapid and quantitative fashion. One of the advantages of flow cytometry methods lies in the ability to obtain population information....
متن کاملDevelopment of an Immunomagnetic Separation Method for Viable Salmonella Typhimurium Detected by Flow Cytometry
Corresponding Author: Shakil Ahmed Department of Biotechnology, Flensburg University of Applied Sciences, Kanzleistr.91-93, 24943 Flensburg, Germany Email: [email protected] Abstract: A very small number of bacterial pathogens may have fatal effects on food safety. In spite of having great advancements in bioanalytical methods, most of the accepted detection methods are still cultiva...
متن کاملClinical relevance of anti-HLA antibodies detected by flow-cytometry bead-based assays--single-center experience.
The purpose of this study was to define the incidence, dynamics, and profiles of anti-human leukocyte antigen antibodies (HLA-Abs) produced after kidney transplantation and their impact on graft outcome. A total of 72 first cadaver donor kidney recipients were prospectively monitored for the development of HLA-Abs using bead-based flow-cytometry assays (One Lambda FlowPRA tests). Sixteen recipi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Visualized Experiments
سال: 2010
ISSN: 1940-087X
DOI: 10.3791/2066