Ionization chamber gradient effects in nonstandard beam configurations
نویسندگان
چکیده
منابع مشابه
Time Response of a Gridded X-ray Beam Ionization Chamber*
Recently, Quick-Scanning Extended X-ray Absorption Fine Structure Spectroscopy (QEXAFS) has become an important tool for in-situ characterization of materials and measurement of associated electronic structure for where samples have a short life due to X-ray damage. In this case, the time response of the ionization chamber affects the measurement resolution and therefore overall performance of ...
متن کاملIonization Chamber Detector for X-ray with Beam Position Monitoring
Ionization Chambers have been commonly used at beamlines in many synchrotron radiation facilities. Typical ADC ion chambers are pictured in Figure 1. The chambers generate a current proportional to the incident X-ray beam intensity. The ionization chamber allows users to determine the change in beam position in a single axis by comparing two signals that are created as the beam passes through t...
متن کاملExperimental and Monte Carlo evaluation of an ionization chamber in a 60 Co beam
Recently a special parallel-plate ionization chamber was developed and characterized at the Instituto de Pesquisas Energéticas e Nucleares. The operational tests presented results within the recommended limits. In order to determine the influence of some components of the ionization chamber on its response, Monte Carlo simulations were carried out. The experimental and simulation results pointe...
متن کاملAbsolute Air-kerma Measurement in a Synchrotron Radiation Beam by Ionization Free-air Chamber
A dosimetric procedure to assure the traceability to the air-kerma standard of the measurements performed in synchrotron radiation beams, was implemented at the “Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti” of ENEA (INMRI-ENEA). To this purpose, absolute air-kerma measurements by the ENEA standard free-air chamber for low energy x-rays have been performed at the SYRMEP (SYnchro...
متن کاملDevelopment of ionization chamber for in-line intensity monitoring of large profile parametric X- ray beam
An in-line ionization chamber has been developed for the real-time measurement of the absolute intensity of the pulsed parametric X-ray (PXR) beam during irradiation experiments. The quasi-monochromatic PXR generating system was developed at the Laboratory for Electron Beam Research and Application (LEBRA) in Nihon University. In contrast to typical narrow X-ray beams in synchrotron radiation f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2009
ISSN: 0094-2405
DOI: 10.1118/1.3213518