Ionic Conductance Changes in Voltage Clamped Crayfish Axons at Low pH
نویسندگان
چکیده
منابع مشابه
Ionic Conductance Changes in Voltage Clamped Crayfish Axons at Low pH
Giant axons from the crayfish have been voltage clamped with an axial wire system. General characterististics of observed ionic currents under normal conditions are similar to those measured in other giant axons and in nodes of Ranvier. As the pH of the external bath is lowered below 7, a marked, reversible slowing of potassium currents is seen with little effect on sodium currents. The steady-...
متن کاملBarbiturates Block Sodium and Potassium Conductance Increases in Voltage-Clamped Lobster Axons
Sodium pentobarbital and sodium thiopental decrease both the peak initial (Na) and late steady-state (K) currents and reduce the maximum sodium and potassium conductance increases in voltage-clamped lobster giant axons. These barbiturates also slow the rate at which the sodium conductance turns on, and shift the normalized sodium conductance vs. voltage curves in the direction of depolarization...
متن کاملPotassium flux ratio in voltage-clamped squid giant axons
The potassium flux ratio across the axolemma of internally perfused, voltage-clamped giant axons of Loligo pealei has been evaluated at various membrane potentials and internal potassium concentrations ([K]i). Four different methods were used: (a) independent measurement of one-way influx and efflux of 42K; (b) simultaneous measurement of net K current (IK) and 42K influx; (c) simultaneous meas...
متن کاملSodium flux ratio in voltage-clamped squid giant axons
The sodium flux ratio across the axolemma of internally perfused, voltage-clamped giant axons of Loligo pealei has been measured at various membrane potentials. The flux ratio exponent obtained from these measurements was about unity and independent of membrane voltage over the 50 mV range from about -20 to ł mV. These results, combined with previous measurements of ion permeation through sodiu...
متن کاملEffects of Internal Divalent Cations on Voltage-Clamped Squid Axons
We have studied the effects of internally applied divalent cations on the ionic currents of voltage-clamped squid giant axons. Internal concentrations of calcium up to 10 mM have little, if any, effect on the time-course, voltage dependence, or magnitude of the ionic currents. This is inconsistent with the notion that an increase in the internal calcium concentration produced by an inward calci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of General Physiology
سال: 1974
ISSN: 1540-7748,0022-1295
DOI: 10.1085/jgp.64.6.666