Ion-selective microelectrodes for intracellular measurements.
نویسندگان
چکیده
منابع مشابه
Novel Solid-Contact Ion-Selective Microelectrodes for Localized Potentiometric Measurements
The design and properties of novel type of solid-contact ionophore-based ion-selective microelectrodes are reported. The microelectrode is based on an insulated needle-shaped metallic wire with an exposed apex. The ion-to-electron transducer is made of poly(3-octylthiophene-2,5-diyl) and placed between an ion-selective membrane and the metallic tip. The ion-selective polyvinyl chloride-based me...
متن کاملAptamer-based potentiometric measurements of proteins using ion-selective microelectrodes.
We here report on the first example of an aptamer-based potentiometric sandwich assay of proteins. The measurements are based on CdS quantum dot labels of the secondary aptamer, which were determined with a novel solid-contact Cd2+-selective polymer membrane electrode after dissolution with hydrogen peroxide. The electrode exhibited cadmium ion detection limits of 100 pM in 100 mL samples and o...
متن کاملIon-Sensitive Intracellular Microelectrodes. How to Make and Use Them
the techniques can easily make effective use of the most sophisticated of these methods." This admirable goal is partially achieved in this multiple-author collection. The chapters on velocity sedimentation (by D. Ridge), zonal rotors (by J.M. Graham), and isopycnic centrifugation (by G.D. Birnie and D. Rickwood) take the novice up to the point where he can apply the methods discussed in an int...
متن کاملFunctionalized ZnO nanorod-based selective magnesium ion sensor for intracellular measurements.
ZnO nanorods were grown on a silver-coated tip of a borosilicate glass capillary (0.7 μm in tip diameter) and used as selective potentiometric sensor of intracellular free Mg(2+). To functionalize the ZnO nanorods for selectivity of Mg(2+), a polymeric membrane with Mg(2+)-selective ionophores were coated on the surface of the ZnO nanorods. These functionalized ZnO nanorods exhibited a Mg(2+)-d...
متن کاملIon trapping with fast-response ion-selective microelectrodes enhances detection of extracellular ion channel gradients.
Previously, functional mapping of channels has been achieved by measuring the passage of net charge and of specific ions with electrophysiological and intracellular fluorescence imaging techniques. However, functional mapping of ion channels using extracellular ion-selective microelectrodes has distinct advantages over the former methods. We have developed this method through measurement of ext...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Folia Pharmacologica Japonica
سال: 1993
ISSN: 0015-5691,1347-8397
DOI: 10.1254/fpj.102.271