Iodide-selective membrane electrode based on salophen complex of cobalt (III)
نویسندگان
چکیده
منابع مشابه
Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
متن کاملiodide selective membrane electrode based on copper (π)-bis-nphenilsalicyldenaminato complex
an iodide ion-selective pvc membrane sensor based on copper (π)-bis-nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mv per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol l-1,...
متن کاملHighly selective iodide membrane electrode based on a cerium salen.
A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detec...
متن کاملHighly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
متن کاملPerchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier.
A synthesized bis(dibenzoylmethanato)Co(II) complex (Co(DBM)(2)), has been used as a ionophore for the preparation of a new perchlorate ion-selective electrode. The electrode exhibits a Nernstian response over the perchlorate concentration range of 8.0x10(-7)-1.0x10(-1)M with a slope of 60.3+/-0.5 mV per decade of concentration. The limit of detection as determined from the intersection of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 2005
ISSN: 0103-5053
DOI: 10.1590/s0103-50532005000400013