Investigation on the performance of fluted tube-in-tube gas cooler in transcritical CO2 heat pump water heater

نویسندگان

چکیده

The utilization of fluted inner tube in tube-in-tube heat exchangers is an effective way to improve the transfer performance. Based on segmented model, performance a gas cooler (FTGC) transcritical CO2 pump water heater was studied this paper. simulation model validated and adopted numerically investigate effects different parameters cooler, which compared smooth (STGC) with same geometric parameters. results showed that FTGC had higher capacity most conditions. rate first increased then decreased as inlet pressure increased. temperature difference at pinch point lower than STGC. In FTGC, position mainly influenced by outlet temperatures. Regarding system COP, improvement maximum COP could be up 29.41% using STGC when 10 °C 80 °C. However, 40 °C, impaired 12.98%. Through changing designs fixed total area, temperatures were 60 highest obtained design used experiments.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance study on solar assisted heat pump water heater using CO2 in a transcritical cycle

This study reports the numerical analyses of a CO2 transcritical cycle on solar assisted heat pump water heating system in which evacuated tube U-pipe solar collector is utilized as an evaporator. This simulation model can predict operating characteristics for moderate meteorological conditions of North Dakota. The main purpose of this work is to simulate the overall performance of the heat pum...

متن کامل

Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater

Besides compressor rotary speed and parameters of water flowing through gas cooler and evaporator, refrigerant charge amount and electronic expansion valve (EEV) opening are two important parameters that have significant effects on the performance of a transcritical CO2 heat pump system. In this study, the effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump ...

متن کامل

Field Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control

Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...

متن کامل

Experimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater

The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the charac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Refrigeration-revue Internationale Du Froid

سال: 2022

ISSN: ['1879-2081', '0140-7007']

DOI: https://doi.org/10.1016/j.ijrefrig.2021.12.011