Investigation of turbine blade failure in a thermal power plant
نویسندگان
چکیده
منابع مشابه
Investigation of blade failure in a gas turbine
A gas turbine abruptly tripped to a stop during its daily morning start-up period. Out of a total of 81 blades in the first row only one blade was broken at its root. Prior to this accident, there were three blade failure accidents in the same plant during the last 10 years. First, the fracture surface of the troubled blade was investigated. Stress analysis of the blade showed that the maximum ...
متن کاملMetallurgical fatigue failure analysis of the brazed steam turbine blade
In this paper, failure mechanism of a 17th stage blade of an 82.5 MW steam turbine that caused damage to the internal turbine compartment and the adjacent blade equipment has been studied. In order to determine the cause of failure and prevent similar events, various metallurgical and mechanical investigations including chemical composition analysis, metallography and microstructural analysis, ...
متن کاملMetallurgical fatigue failure analysis of the brazed steam turbine blade
In this paper, failure mechanism of a 17th stage blade of an 82.5 MW steam turbine that caused damage to the internal turbine compartment and the adjacent blade equipment has been studied. In order to determine the cause of failure and prevent similar events, various metallurgical and mechanical investigations including chemical composition analysis, metallography and microstructural analysis, ...
متن کاملGas Turbine Power Plant System: A Case Sudy of Rukhia Gas Thermal Power Plant
The reliability of the GTPPS were analyzed based on a five and half -year failure database. Such reliability has been estimated by selecting Proper model and different models for repairable system analysis were discussed. The reliability estimation by using Nonhomogenious process and Homogenous renewal Process are explained. Non Homogeneous Process was further divided into Power law Process and...
متن کاملEfficiency Assessment of Acoustic Cabin for Providing Acoustic Comfort in Turbine Unit of a Thermal Power Plant
Background and Objective: A practical method for noise control in environments with different noise sources is designing an acoustic cabin for the workers. In this regard, this study aimed to assess the efficiency of the acoustic cabin in a typical turbine unit of a thermal power plant to provide acoustic comfort. Materials and Methods: Measurement of the noise level and spectrum, as well as v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Studies in Engineering Failure Analysis
سال: 2013
ISSN: 2213-2902
DOI: 10.1016/j.csefa.2013.07.002