Investigation of Strengthening Reinforced Concrete Beam-Column Connection Wrapped with Fiber-reinforced Polymer

نویسندگان

چکیده

In reinforced concrete structures, the beam-column connection area has a considerable influence on behavior of structure. The use fiber-reinforced polymer FRP to strengthen connections in Reinforced structure can be one solutions transform this area, thus improving structure, which is achieved through carbon achieve high-strength Investigations have been conducted using finite element modeling. damage plasticity model used analyze model. results show that bearing capacity developed considerably, but ductility also significantly reduced. study evaluated qualities various reinforcement models and proposed most effective flex zone with fibers oriented at forty-five degrees shear joint showed significant changes behavior. demolition joints sudden failure without prior notice, since collapse column before break beam are undesirable, their occurrence cause irreparable damage.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates

Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP) laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as ...

متن کامل

Full Scale Reinforced Concrete Beam-Column Joints Strengthened with Steel Reinforced Polymer Systems

This paper presents the results of an experimental campaign performed at the Laboratory of Materials and Structural Testing of the University of Salerno (Italy) in order to investigate the seismic performance of reinforced concrete (RC) beam-column joints strengthened with steel reinforced polymer (SRP) systems. With the aim to represent typical façade frames’ beam-column subassemblies found in...

متن کامل

Axial Compressive Strength of Reinforced Concrete Columns Wrapped with Fiber Reinforced Polymers (FRP)

This paper presents the results of a study on the axial compressive strength of columnsstrengthened with FRP wrap. The experimental part of the study included testing 6 reinforcedconcrete columns in two series. The first series comprised three similar circular reinforced concretecolumns strengthened with FRP wrap. The second series consisted of three similar square columns,two with sharp corner...

متن کامل

Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection

In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well w...

متن کامل

Flexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars

Fiber-reinforced polymer (FRP) reinforcing bars have aTtracted considerable 0llellli0l1 for applications where corrosion of steel reinforcement is problemaric. Due 10 rhe generally low elastic modulus and poor bond clwracreristics of FRP as coil/pared 10 steel reinforcing bars, the use of FRP results in IGI:i?er crack widlhs under senJice loads. Fiber-reinforced concrete (FRe) is proposed for u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of studies in science and engineering

سال: 2022

ISSN: ['2789-634X']

DOI: https://doi.org/10.53898/josse2022214