Tomographic Reconstruction of Uniformly Redundant Penumbral Array Camera

Penumbral imaging is a powerful imaging technique for radiations with long mean-free path. Since the reconstruction is based on deconvolution, the technique is sensitive to noise contained in penumbral images. Uniformly redundant penumbral array (URPA) technique can improve the SN ratio of penumbral images. In URPA, the penumbral apertures are arranged in m-sequence. In the reconstruction proce...

متن کامل

Uniformly Redundant Arrays

Uniformly Redundant Arrays (URA’s) are two–dimensional binary arrays with constant sidelobes of their periodic autocorrelation function. They are widely agreed upon to be optimum mask patterns for coded aperture imaging, particularly in imaging systems with a cyclic coded mask. In this paper, a survey of all currently known construction methods for URA’s is given and the sizes and open fraction...

متن کامل

detection of volatile compounds of medicinal plants with some nano-sorbents using modified or new methodologies and investigation of antioxidant activity of their methanolic extracts

in this work, a novel and fast method for direct analysis of volatile compounds (davc) of medicinal plants has been developed by holding a filament from different parts of a plant in the gc injection port. the extraction and analysis of volatile components of a small amount of plant were carried out in one-step without any sample preparation. after optimization of temperature, extraction time a...

Positron tomography of breast cancer in a community hospital: A case study of advanced disease using a coincidence gamma camera

Until recently PET scanning has been available only at major universities or teaching hospitals possessing the necessary resources and expertise to operate a research PET facility. Most dedicated PET centers cost several millions of dollars, and include a cyclotron, a radiochemistry laboratory to synthesize PET radiopharmaceuticals, a multicrystal dedicated PET camera, advanced computer f...