Investigation of matrix independent calibration of oxygen in Glow Discharge Optical Emission Spectrometry

نویسندگان

چکیده

The performance of Glow Discharge Optical Emission Spectrometry for matrix independent oxygen determination was investigated using the spectral lines atomic at 130 nm and 777 standard...

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of matrix-specific calibrations for oxygen in analytical glow discharge spectrometry

The performance of glow discharge optical emission spectroscopy and mass spectrometry for oxygen determination is investigated using a set of new conductive samples containing oxygen in the percent range in three different matrices (Al, Mg, and Cu) prepared by a sintering process. The sputtering rate corrected calibrations obtained at standard conditions for the 4 mm anode (700 V, 20 mA) in GD-...

متن کامل

Rf glow discharge optical emission spectrometry for the analysis of arrays of Ni nanowires in nanoporous alumina and titania membranes

During the last decade, a great variety of nanostructures (nanotubes, nanofibers or nanowires) based on metals, carbons, polymers or semiconductors, have been synthesized following different synthesis procedures by using nanoporous anodic alumina membranes (AAM) as templates [1]. The principal reason for using templates of nanoporous AAM as precursor patterns lies on the possibility to obtain, ...

متن کامل

Spatially-resolved observation of the excitation temperature in a glow discharge plasma for atomic emission spectrometry.

A two-dimensionally imaging spectrometer system was employed to obtain the spatial distribution of the excitation temperature in a glow discharge plasma for emission analysis. A Grimm-style glow discharge excitation source, whose hollow anode had an inner diameter of 8 mm, was observed over the whole emission area. The mapping of the excitation temperature was conducted by using a two-line meth...

متن کامل

Spatially-resolved observation of glow discharge plasma for atomic emission spectrometry.

An imaging spectrograph equipped with a CCD detector was employed to measure two-dimensional emission images from a glow discharge plasma in atomic emission spectrometry. The emission images at Zn I 334.50 nm for a zinc sample and at Cu I 324.75 nm for a copper sample could be obtained. Their emission intensities were not uniform in the radial direction of the plasma region but became weaker at...

متن کامل

Investigation on the erosion/deposition processes in the ITER- like Wall divertor at JET using Glow Discharge Optical Emission Spectrometry technique

As a complementary method to RBS, GDOES (Glow Discharge Optical Emission Spectrometry) was used to investigate the depth profiles of W, Mo, Be, O and C concentrations into marker coatings (CFC/Mo/W/Mo/W) and the substrate of divertor tiles up to a depth of about 100 m. A number of 10 samples cored from particular areas of the divertor tiles were analyzed. The results presented in this paper ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Analytical Atomic Spectrometry

سال: 2022

ISSN: ['1364-5544', '0267-9477']

DOI: https://doi.org/10.1039/d2ja00043a