Investigation of Load-Bearing Capacity for Reinforced Concrete Foundation Retrofitted Using Steel Strut–Tie Retrofit System
نویسندگان
چکیده
To reduce the thickness of reinforced concrete foundation members used in construction and structural applications, a previous study developed tested strut–tie retrofit system installed foundations. This proposes optimum details steel-tie for with reduced via finite element simulation-based load-bearing capacity assessment. The parameters (structural steel type, plate thickness, number strut frames) that significantly affected capacities were optimized by comparing maximum effective stress code-defined allowable limits. compared those computed using model. Based on assessment design loading combinations, can be transverse (by 55%) longitudinal 87%) directions designed model approach.
منابع مشابه
Stepwise Regression for shear capacity assessment of steel fiber reinforced concrete beams
The addition of steel fibers into concrete improves the postcracking tensile strength of hardened concrete and hence significantly enhances the shear strength of reinforced concrete reinforced concrete beams. However, developing an accurate model for predicting the shear strength of steel fiber reinforced concrete (SFRC) beams is a challenging task as there are several parameters such as the co...
متن کاملOptimal Retrofit Design of Reinforced Concrete Frame with Infill Wall Using Fiber Reinforced Plastic Materials
Abstract—Various retrofit techniques for reinforced concrete frame with infill wall have been steadily developed. Among those techniques, strengthening methodology based on diagonal FRP strips (FRP bracings) has numerous advantages such as feasibility of implementing without interrupting the building under operation, reduction of cost and time, and easy application. Considering the safety of st...
متن کاملCalibration of Load and Resistance Factors for Reinforced Concrete
Current approach for designing of reinforced concrete members is based on the load and resistance factor. However the load and resistance parameters are random variables, the constant values have been designated for them in the designing procedure. Assuming these factors as the constants, will be led to the unsafe and uneconomical designs. Safe designing of structures requires appropriate recog...
متن کاملPrediction of axial load capacity of stub circular concrete-filled steel tube using fuzzy logic
a r t i c l e i n f o Keywords: Concrete-filled steel tube (CFST) Confinement effect Fuzzy logic Modified learning from example (MLFE) Axial load capacity A circular concrete-filled steel tube (CFST) has several advantages compared with the conventional reinforced concrete member or hollow steel tube, since the tri-axial state of compression of the concrete infill increases its strength and str...
متن کاملSome Studies on Steel Fiber Reinforced Concrete
Fibres are generally used as resistance of cracking and strengthening of concrete. In this project, I am going to carry out test on steel fibre reinforced concrete to check the influence of fibres on flexural strength of concrete. According to various research papers, it has been found that steel fibres give the maximum strength in comparison to glass and polypropylene fibres. Hence, in this pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sustainability
سال: 2023
ISSN: ['2071-1050']
DOI: https://doi.org/10.3390/su151310372